UMG 604 E-PRO 230V (UL) (Fortop) | Power analyser

Welke lengte heeft u nodig?
/
U heeft 0 stuks nodig voor 0 euro incl. BTW
UMG 604 E-PRO 230V (UL) (fortop)
1.150,00 1.391,50 Incl. VAT
Ask for quotationAdd to wish list
Delivery time on request
Add to favorites
UMG 604 E-PRO 230V (UL) (Fortop) | Power analyser
UMG 604 E-PRO 230V (UL) (Fortop) | Power analyser
1.150,00
  • Product description and specifications
  • Documents
  • Ask a Question
  • Related products

Barcode

Product description

Electrical disturbances, whether they are short interruptions, voltage dips, or harmonics, can have far-reaching consequences for critical applications such as hospitals, data centers, and the process industry. These disturbances can lead to high costs and unforeseen downtime. The Janitza UMG 604-PRO Power Analyser not only promises to recognize these problems but also enables users to intervene directly by sending notifications via email.

The UMG 604-PRO is not just any power analyser. The device combines several functions, including a PQ analyser, kWh meter with 8 tariffs, IP gateway, logger, PLC, and web server - all housed in one compact enclosure.

With the integrated web interface of the UMG 604-PRO, users can directly view the power quality status of their installation. This website is user-friendly and accessible via various devices, from PCs to smartphones. Moreover, the analyser offers the possibility to automatically generate reports for voltage and current according to the prevailing IEC 61000-2-4 standards, thus quickly identifying and addressing any problems.

Technically, the UMG 604-PRO performs Fourier analyses up to the 40th order and determines more than 800 variables every 200 milliseconds. In addition, there is continuous sampling of all voltage and current channels at 20kHz, allowing the device to perform accurate measurements and analyses.

Thanks to various protocols, including RS485 (Modbus RTU and Profibus) and Ethernet TCP/IP, the UMG 604-PRO can be easily integrated into existing installations.

Main features of the UMG 604-PRO power analyser:
  • Analyses consumption, disturbances/events, and power quality
  • Detection of short interruptions, dips, harmonics, and slow voltage variations
  • Notifications via email
  • Combines functions: PQ analyser, kWh meter, IP gateway, logger, PLC, and web server
  • Integrated web interface accessible to 5 different devices simultaneously
  • Automatic reporting of power quality according to IEC61000-2-4 standard
  • Integrated temperature measurement, input for pt100/pt1000
  • Measurement of power quality parameters up to the 40th harmonic order
  • Recording of transients
  • Storage capacity of 510 million measurement values in 128Mb memory
  • Including English-language configuration software GridVis® essentials.

Documents

Specifications

MountingDIN-rail
SeriesUMG 604-PRO
Communication interface

A communication interface is a physical or software-based connection between two systems or devices, enabling them to communicate and exchange data.

Communication interfaceEthernet
RS232
RS485
Digital inputs2
Digital outputs2
Analogue inputs1
Communication protocol

A communication protocol is a set of rules and standards used to enable the exchange of data between different devices or systems.

Communication protocolModbus RTU
Modbus TCP
BACnet IP (option)
Memory

Janitza measuring instruments are equipped with memory, allowing measurement values to be stored in memory for extended periods of time.

Memory128 MB
Auxiliary voltage

Auxiliary voltage is the additional voltage required to supply a device with power for proper operation and measurements.

Auxiliary voltage135...340 VDC
95...240 VAC
User interfaceWeb interface
LCD screen
Harmonics

A harmonic is a frequency that is an integer multiple of the fundamental frequency. The fundamental frequency is the lowest (natural) frequency that a system exhibits by default. A natural frequency of a system is a frequency that the system can inherently exhibit.

HarmonicsU/I to 40th order
Event registrationDips(ms)
Peaks
Transients(us)
Reportso.a. kWh / voltage quality
BrandJanitza
CategoryPower analysers
Product codeJA500415
Supplier code5216206
Unitst

Related products

GridVis Expert, basic package with 10 items | Software
3.680,00 4.452,80 Incl. VAT
Product code: JA901943
GridVis Expert, basic package with 25 items | Software
6.900,00 8.349,00 Incl. VAT
Product code: JA901944
GridVis Expert, basic package with 50 items | Software
9.650,00 11.676,50 Incl. VAT
Product code: JA901945
GridVis Standard, basic package with 10 items | Software
1.480,00 1.790,80 Incl. VAT
Product code: JA901920
GridVis Standard, basic package with 25 items | Software
2.760,00 3.339,60 Incl. VAT
Product code: JA901921

Ask a question about this product

         

Shopping cart

Quotation list

Clear filters

Filter

Cancel
Confirm